Product Details:
Minimum Order Quantity | 10 Piece |
No.of Poles | Double Pole |
Rated Current | 16 A |
Brand | Siemens |
Breaking Capacity | 10 kA |
Frequency | 50 Hz |
Voltage | 415 V |
Phase | Three Phase |
Item Model Number | C32 5SL62327RC |
Product Dimensions | 15 x 15 x 15cm |
Primary material | Plastic |
Weight | 4300g |
Overload currents can occur, for example, when several electrical consumers are used simultaneously in the same circuit and exceed the maximum permissible current level. Short circuits, on the other hand, are conductive connections caused by errors, e.g. between phase and neutral conductor. Short circuits and overload currents can occur quite suddenly, for example, as a result of incorrect operation during switching, assembly errors or cases of higher forces, such as lightning strikes, earthquakes or flood disasters. It’s far more common, however, for them to occur gradually, as a result of age-related faults in cable insulation, plug connections or broken cables.
|
The risk of overload and short circuit is particularly high in residential and functional buildings, where the installed electrical systems and equipment are not subject to regular inspection. The growing number of electrical devices also contributes to the problem: an average household today uses much more than 50 electrical devices, compared to less than eight previously. Decentralized power producers like photovoltaic systems, or charging electric vehicles, place entirely new demands on electrical systems that may have been installed decades ago, according to the state-of-the-art at the time, but now require expanded protection measures. The same applies to industrial environments: just a few seconds without power is enough to bring production lines to a standstill, disrupt automation systems or compromise entire production batches. Preventive protection of industrial systems against electrical faults and downtimes is therefore essential, especially with the increasing use of automated operating processes.
Miniature circuit breakers (MCBs) from the SENTRON portfolioMCBs from the SENTRON portfolio meet the enhanced requirements of automated buildings and industrial power supply systems, e.g. in the automotive and semiconductor industry or in data centers. Compared to residential and functional buildings, these are usually more extensive and complex in terms of both network topology and operation. Electricity and production downtimes must be deliberately prevented in these cases using coordinated device combinations if economic losses are to be avoided. Our MCBs protect wires and cables in cases of short circuit and overloads, and also enable backup protection for switching devices and also semiconductor protection. They are therefore a fundamental component in end-to-end protection concepts
Product Details:
No. of Poles | 3 Pole |
Usage | for Transformers |
Relay Type | Electrical Overload Relay |
Brand | Siemens |
Phase | Single phase |
Product Details:
No.of Poles | Double Pole |
Rated Current | 32A |
Brand | Siemens |
Breaking Capacity | 15 kA |
Frequency | 50 Hz |
Voltage | 415 V |
Phase | Single |
Country of Origin | Made in India |
Product Details:
Minimum Order Quantity | 10 Piece |
Rated Current | 125 A |
Rated Voltage | 600V |
Material | Plastic |
Pole | 2 Pole |
Color | White |
Country of Origin | Made in India |
Product Details:
Minimum Order Quantity | 5 Piece |
No. of Poles | Double Pole |
Brand | Schneider |
Breaking Capacity | 25kA |
Voltage | 415V |
Certification | IS Certified |
Rated Current | 100A |
Product Details:
Minimum Order Quantity | 1 Piece |
No.of Poles | Triple Pole |
Brand | Schneider |
Phase | Three phase |